Description
Its ability to accept overloads of about 10 In makes it particularly interesting for the switching of incandescent lamps.
Dimensions
Connection
Operation principle
Voltage range :
* 19 to 53 V AC Eff
* 90 to 240 V AC Eff
Min hold current :
* for U = 240 VAC Eff : 70 mA
* for U = 20 V AC Eff : 200 mA
Courant résiduel max : 3 mA (non excité)
Facteur de marche : 50%.
Example of applications :
* luminous alarm blocks
* control of warning lights for road traffic
* Warning lights on superstructures (water towers, cranes, aerials, civil engineering building sites, factories chimneys, ships masts, airports...)
* Services advertising
* luminous beacons.
(see following schematic)
Plan
Technical features
Function | Flashing |
Presentation | Under case |
Storage temperature | -40 to +85°C |
Weight | 100 g. |
Coil data
Direct current | Alternative current | ||
Min. nominal voltage DC | 19 V | ||
Min. nominal voltage AC | 240 V |
Contacts
Short-circuit load | 20 ms / 80 A max |
Contacts rating
ALTERNATIVE CURRENT | ||||
|
Versions
Other versions can be realized upon request :
* Specific frequencies (0,5 Hz, 2 Hz)
* Duty cycle 40%
* dual rythm flashing
* flashing with alternated outputs