Tyristor Switches
- Dimensions according to power size
- Control signal: Relay, Voltage (DC)
- Output voltage (Vac): up to 500
- Output current (A): up to 350
- Half wave pulses without dc components QUICK TAKT
- Communication Interfaces (optional):
* DeviceNet
* Modbus RTU
* PROFIBUS DPV1
* Ethernet
* CANopen
- Diagnostic LED
Control Inputs:
Digital input
- Free Voltage
- Voltage input 0...24V
- UH (1 status): >3 Vdc
Process outputs
- Voltage Rating (Vac):
230 (1S), 400, 500
- Nominal Current (A):
16, 30, 45, 60, 100, 130, 170, 280, 350
- Load Type:
* Resistive
* Infrared
with transformer
Functions
Operating Mode:
- Half wave pulses without dc components QUICK TAKT
- Zero crossing switching
Communication and programming:
Interfaces
(Optional accessory for multiple modules)
Communication protocols :
- DeviceNet
- Modbus RTU
- PROFIBUS DPV1
- Ethernet
- CANopen
Installation
Case dimensions:
(Lenght x height x depth)
From 45 x 136 x 129 to 375 x 430 x 261 mm
according to power size
Power circuit wiring:
- Single phase (1S)
- Symmetrical loads in three phase economy circuit operation (2S)
- Three phase operation (3S)
Operating temperature:
-10... +45°C (natural ventilation)
-10... +35°C (forced cooling)
Up to 55°C with performance degradation of 2%/°C
Display and indicators
Indications:
- LEDs
Connectable to:
- Any controller from Ascon Tecnologic range with the appropriate I/Os
Certifications : CE, UL
Integrated protection against contact
USB interface