Gessmann’s master controller system TBC 01 is specially designed for usage in railway
applications. Their robust design which is based on the relevant standards EN-60077,
UIC 612 and EN-50155 guarantees low life cycle costs and a maintainability over a period
of 35 years.
Technical data
Ambient temperature outside vehicle -40°C to +50°C->EN 50155 Class T1, T2, T3, TX
Nominal supply voltage 24VDC with variations according to EN 50155
Shock and vibration According to EN 61373
Electromagnetic compatibility (EMC) According to EN 50121-3-2
Isolation and high voltage test According to EN 50155
Pollution degree PD 3 according to EN 60077-1 (others on demand)
Fire and smoke Compliant to EN 45545, (HL3) (others on demand)
Mechanical endurance 10 million operating cycles
Electrical endurance Minimum operating cycle class C3/A3
According to EN 60077-2