TH-PX

High-performance power controller

- Dimensions according to power size (similar to THP)
- Control signal: Voltage, Current or potentiometer
- Output voltage (Vac): up to 690
- Output current (A): up to 2900
- Operating Modes: Full wave TAKT, Phase angle VAR, Voltage sequence control with phase angle VSC_VAR
- Start-up Modes: RAMP, Softstart-softdown SSSD, MOSI
- Anybus Communication Interfaces (optional): Modbus RTU/TCP, PROFIBUS DPV1, PROFINET, DeviceNet, EtherNet/IP, EtherCAT
- LCD display and LEDs
- Integrated load circuit monitoring
- Main load optimisation includes fully digital dASM operation in TAKT mode
- New Thyro-Touch display enables intuitive operations
- Multizone feature: uses TH2PX and TH3PX as two or three single-phases units
Control Input: Voltage (V): 0/1...5V, 0/2...10V, Current (mA): 0/4...20 mA, Potentiometer: 5...10 kΩ
- Control accuracy: ±0.5%
Process outputs: Voltage Rating (Vac):
P500: 230 -20%... 500 +10%
P690: 500 -20%... 690 +10%
- Nominal Current (A): 500 V: 16, 37, 75, 110, 130, 170, 280, 350, 495, 650, 780, 1000, 1500
(3P: 1850, 2600), (2P: 2000, 2750), (1P: 2100, 2900)
690 V: 80, 200, 300, 500, 780, 1400 (3P: 1700, 2200), (2P: 1850, 2400), (1P: 2000, 2600)
- Load Type: Inductive, Tranformer, Resistances with high or low
Rh/Rc temperature coefficient (up to 20:1)
- 3 alarm relays
Functions:
Operating Modes: Full wave TAKT, Phase angle VAR, Voltage sequence control with phase angle VSC_VAR
Start-up Modes: RAMP, Softstart-softdown SSSD, MOSI

Control methods:
- Voltage V, V², Current I, I², Power VxI

- No control Limitations: V, I, P, I peak (MOSI)

Communication and programming:
Connectivity

- RS232
- modules slots
- USB
- I/O bus
Communication protocols  via Anybus modules :
- Modbus RTU/TCP
- PROFIBUS DPV1
- PROFINET
- DeviceNet
- EtherNet/IP
- EtherCAT

Installation

Case dimensions:
(Lenght x height x depth)
From 150 x 320 x 232 to 593 x 1094 x 474 mm
according to power size
Power circuit wiring:
- Single phase (1A)
- Symmetrical loads in three phase economy circuit operation (2A)
- Three phase operation (3A)
Operating temperature: 170 A: 0... +45°C (natural ventilation) - From 280 A: 0... +35°C (forced cooling)

Display and indicators

Status indication: 7 programmable diagnostic LEDs
Indications: LEDs, 3 relays, Thyro-Touch display

Connectable to any controller from Ascon Tecnologic range with the appropriate I/Os

Certifications : CE, UL