DIN RAIL mount mini-programmer controller
Process inputs:
1 temperature probe input:
- Thermocouples: J, K, R, S,T
- PTC KTY81-121 (990 Ω @ 25 °C)
- NTC 103AT-2 (10KΩ @ 25 °C)
- RTD: Pt100
- Voltage (V): 0..1 V, 0/1...5 V , 0/2...10 V
- Voltage (mV): 0...50 mV, 0...60 mV, 12 ...60 mV
- Current (mA): 0/4...20 mA
- Custom linearisation and IR probes (J.K type)
Overall accuracy: ± (0.5 % span ± 1 digit @25 °C); Tc S: ± (1 % span ± 1 digit @ 25 °C)
2 digital inputs for free voltage contacts
Process outputs:
Up to 4 digital outputs
OUT1: RELAY SPDT, 8A
OUT2: RELAY SPDT, 8A
OUT3/OUT4: RELAY SPST-NO, 5A and SSR Drive
OUT5 (Note1):SSR Drive 0...5Vdc, ±20%, 30 mA max
Power supply:
- 24VDC/VAC
- 100… 240 Vac (50/60 Hz)
Transmitter power supply: 10 V DC (±10%), 20 mA max (Note 1)
Functions:
- ON/OFF control with neutral zone
- PID single action or double action (Heat/Cool) with overshoot control
- Bumpless ramp to set point change
- Start-up delay
- Independent timer with 5 functioning modes (optional)
- Setpoint change from digital inputs
- Digital Setpoint retransmission (Note 2)
- Up to 4 memorized setpoints
- 8 segment programmer with events recovery, 2 events and guaranteed soak (optional)
- Wattmeter for calculating the instantaneous power and energy used
- Counter for days and hours worked with programmable threshold for programmed maintenance
- Compressor protection timer
Autotuning:
- Adaptive Autotuning
- Oscillatory
- Fast
Alarms:
- Up to 3 configurable alarms + loop break alarm
Communication and programming:
Up to 2 simultaneous interfaces
Communication on TTL port to:
- Universal programming key
- Remote display
- RS 485 serial interface with ModBus RTU protocol (optional)
Programming/configuration tools:
- Configurable parameter level “Promotion”
- Configuration software available for PC
Installation:
Mounting method: panel mount
Case dimensions: 35 x 88 mm, h: 88 mm
Front frame protection degree: IP40
Screw terminal block protection degree: IP20
Connections
Communication port connection
5 Pole TTL Port
Signals connection
2 lines of 12 poles 2.5 mm² screw terminals block
(Extractable as option)
Connectable to:
- Programming key A01 for PC connection, backup and other functions
- SCADA for monitoring, traceability and remote management
- DX and DY gateways for remote monitoring
Notes
1) OUT5, SSR output available if transmitter power supply is not used
2) Digital Setpoint retransmission available only with RS485 port option or external adapter from TTL
File no. E362268
Ref. UL 61010-1 CSA 61010-1