GAK
- rear wiring socket with clips ER/GE 2.8
- rear wiring socket / PCB mounting ER/GE
- front wiring socket with clips EVC/GE
- front wiring socket with clips 9876
- front wiring socket / screw terminals EVB/GE
- front wiring socket / screw terminals 9877
Description
Flashing relay with fixed rythm - 4 CO contacts - 3 A.
Pluggable on socket with possible withdrawal clasp. Pins at the standard pitch of 2.54 mm. Possibility of polarization by mounting a male withdrawal claps on the relay and female withdrawal clasp on the socket.
GAK relay is pluggable on the following sockets : EVB/GE, 9877, EVC/GE, 9876, ER/GE 2.8, or ER/GE.
Dimensions
Connection
Operation principle
* Flashing rythm : fixed
* Flashing frequency : 50 to 100 beats per minute
Technical features
Function | flashing |
Presentation | under cover |
Connection | on front or rear wiring socket |
Number of mechanical operations | 30.000.000 |
Operating temperature | - 5°C to + 40°C |
Storage temperature | - 40°C to + 70°C |
Climatic protection | optional reinforced climatic protection |
Dielectric strength | 2000 V eff-50 Hz |
Insulation resistance | NFC 45-202 : C 250 V |
Weight | 60 g. |
Protection level | IP40 (according to NFC 20-010) |
Resistance to mechanical shocks | severity 50 A (NFC 20-608) |
Resistance to vibrations | frequency range : 10-55 Hz (NFC20-616) |
Coil data
Direct current | Alternative current | ||
Min. nominal voltage DC | 24 V | 24 V | |
Min. nominal voltage AC | 230 V | 230 V | |
Operating range | -20/+10% of nominal voltage | ||
Power requirement | 1,5 W |
Contacts
Number of contacts | 4 |
Max. load current | 3 A |
Low power switching | 0,1 VA with min voltage 1 V and/or I min 1 mA |
Contacts rating
DIRECT CURRENT | ||||
|
||||
ALTERNATIVE CURRENT | ||||
|
Versions
. GAK relay with reinforced climatic protection
. GAK relay with other flashing rythm
. GAK relay with specific voltages.
Homologations & conformities :
NFC 45-250
CEI 255.1.00